American Time DSY261RSAE Manuel d'installation et d'utilisation - Page 9
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} American Time DSY261RSAE. American Time DSY261RSAE 19 pages. Digital clock/elapsed time indicator with code blue
DSY261RSAE Owner's Manual
The ATSTCS Control Station can be mounted to a double gang box, 1
mounted up to 30 feet away from the Digital Clock/Timer. The recommended minimum interconnecting field wire size is
#22.8 AWG stranded wire. Ensure that installation conforms to the National Electrical Code and local wiring codes.
CAUTION: Electric Shock Hazard! Ensure that no electrical power is present on any wire before installation.
u
Pull interconnecting field wires into the double gang box.
v
Connect field wiring interconnecting the ATSTCS Control Station with the Digital Clock/Timer to the
appropriate wires of the Control Station. See wiring detail below.
w
Mount the Control Station to the double gang box using the machine screws provided.
CHASSIS
NEUTRAL
120 VAC
50/60Hz
Typical wiring for the Digital Clock/Timer with Control Station
© American Time
Control Station Installation
/
inch deep or deeper. The Control Station can be
1
2
RESET
PIEZO
ENTER
BUZZER
30 ft. maximum #22
AWG wire (minimum)
with
/
1
32
(minimum)
SET
RUN
START/STOP
INCREMENT
" insulation
9