American Time DSY261RSxE Manuel d'installation et d'utilisation - Page 9
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} American Time DSY261RSxE. American Time DSY261RSxE 17 pages. Digital clock/elapsed time indicator with code blue
DSY261RSxE Owner's Manual
The ATSTCS Control Station can be mounted to a double gang box, 1
mounted up to 30 feet away from the Digital Clock/Timer. The recommended minimum interconnecting field wire size is
#22.8 AWG stranded wire. Ensure that installation conforms to the National Electrical Code and local wiring codes.
CAUTION: Electric Shock Hazard! Ensure that no electrical power is present on any wire before installation.
u
Pull interconnecting field wires into the double gang box.
v
Connect field wiring interconnecting the ATSTCS Control Station with the Digital Clock/Timer to the
appropriate wires of the Control Station. See wiring detail below.
w
Mount the Control Station to the double gang box using the machine screws provided.
Green-Earth Gnd
Red-Optional
correction line
White-Neutral line
Black-Hot line
© American Time
PIEZO
BUZZER
ATSTCS Control Station
Typical wiring for the Digital Clock/Timer with Control Station
Control Station Installation
/
inch deep or deeper. The Control Station can be
1
2
Digital Clock/Timer
RESET
ENTER
SET
RUN
START/STOP
INCREMENT
20 ft. supplied cable. Can
be extended to 30 ft.
maximum using #22 AWG
wire (min.) with 1/32"
insulation (min.)
9