Dongil Z Fire ZF-170ID Manuel de l'utilisateur - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Dongil Z Fire ZF-170ID. Dongil Z Fire ZF-170ID 10 pages. Indirect air forced heater

Do not leave the place with the heater turned on or plugged in.
Nozzle
Nozzle should be cleaned or replaced at least once a year. If contaminated
fuel is used, the nozzle should be replaced immediately. To clean the
nozzle, take it out from the burner, disassemble it, put it in the thinner or
gasoline for a while and carefully assemble it.
Ignition Plug
Ignition plug should be cleaned or the gap between the electrodes should be
adjusted every 600 hours or at any necessary time. Take it out from the
burner and clean it with steel brush. The gap between the electrodes should
be kept 3.5mm~3.7mm.
Photo-electric tube
Photo-electric tube should be cleaned once a year or at any necessary time.
Clean the photo-electric surface with some cotton cloth dipped in the water
or alcohol.
Photo-electric tube
Air bolwing Motor
Photo-electric tube holder
Air blowing Fan
Burner Head
Lgnition Plug
Support Piece
ZF-170ID
ZF-240ID
Diffusion
Nozzle
Burner head blade
Spark plug
ZF-80ID
Igniter
High pressure fuel hose
Nozzle
Ignition Plug
Distributor
Diffuser
Fitting Bolt
Burner head
Photocell
Blower fan
Blower motor
Indirect Air Forced Heater

Long-Time Storage

1. Open the fuel tank cap.
2. Remove the fuel with a bellow.
3. Clean the inside of the tank with some kerosene, gasoline or thinner.
Never use water at this time because rust may be fatal.
4. Dry the tank completely.
Never pass the season with the fuel in the tank. Old fuel may give damage
to the product.
Store the product at the dry and well-ventilated area.
Store the product at the place of no dust and moisture in the original
packing box.
Keep the user manual at the place close at hand.
First-Aid Measure
(Measure to the error codes displayed on the
temperature display window)
Display
Cause
Window
Power switch handling error
EO
Power is supplied when
the switch is on.
Flame Detector (Photo-electric tube error)
1.Photo-electric tube defect
3.Incomplete Combustion
E1
3.Contamination of photo-electric tube
4.Contamination of fuel filter
-Ignition trouble
E2
1.Temperature sensor separation
2.Sensor Defect
Anti-overheating Sensor Defect
E3
Unusual internal overheating
E6
Shortage of Fuel
LO
In case of below 9 C
Hi
Incase of over 50 C
Blinking
Electronic Circuit Board Defect
7
Measure
After plugging it out and turning
the switch off, plug it in and
turn on the switch.
1.Replacement of Photo-electric tube
2.Replacement to clean fuel
3.Cleaning of photo-electric tube
4.Cleaning of fuel filter
1.Checking the igniter wire
2.Cleaning or replacement
of ignition plug
Temperature sensor error
1.Re-connection of the sensor
Replacement of temperature sensor
-Re-operating after cooling
Float Sensor
Fuel Supply
Normal
Normal
1.Checking the circuit
2.Re-operating after reset