TROUBLE SHOOTING
NO POWER TO THE DISPLAY:
Power point is faulty. Test power point with a known working appliance. If the power point is operational, check the
controller in another power point and if there is still no display then send the controller for repair.
RTC-FAIL
– This can occur if the unit has been turned off for a prolonged period of time, leave the unit on for ~30
seconds, then turn it off for ~30 seconds before turning it back on.
PIPE/ROOF SENSOR FAULTS
:
The following are error messages caused by pool or roof sensor faults;
SENSOR DISCONNECTED OR OPEN CIRCUIT
Sensor cable unplugged from controller, cable damaged, bad cable join or sensor is damaged.
SENSOR SHORT CIRCUIT OR REVERSED
Sensor cable or cable join polarity is incorrect, or sensor is damaged. The positive side of the cable (grey coloured
wire) should be wired to the righthand side of the plug, with the screws facing towards you and the sensor cable
entry at the bottom of the plug. If the cable has been joined ensure no polarity reversal occurs.
ISOLATING SENSOR FAULTS
:
Swap the sensor locations. Put the pipe sensor in the roof socket and the roof sensor in the pipe socket.
If the fault moves from pipe to roof or vice versa then it is likely that there is a sensor fault.
If the fault remains the same then the controller may need to be repaired.
PUMP FAULTS:
Ensure the controller has working sensors; otherwise the pump will not operate.
CIRCULATION PUMP WILL NOT START:
Ensure that the Circulation pump is plugged into the Aquasmart5 SV PUMP power socket properly.
Check the AUX Heating and Solar Heating times set in the Aquasmart5 SV controller, adjust if required.
If it still won't start plug the filtration pump straight into a power point and turn on. IF the pump doesn't start then
you have an issue with your pump. If the pump is ok, your controller requires repair.
PUMP WILL NOT STOP
:
Turn off power to the controller and ensure the pump stops. If the pump continues to operate then unplug it from
the power point and connect it to the 240Vac socket marked PUMP at the bottom of the controller.
If the pump is plugged into the controller and won't stop, check to see what is displayed on the controller screen. The
controller may be running for heating purposes.
If the pump is still running, and the controller states that nothing should be running, your controller requires repair.
10