STEP 3 EASY TAP ADAPTER INSTALLATION
A. Turn off cold water supply to the sink faucet
and relieve pressure by opening the cold
water faucet. (Repair any existing plumb
ing sink leaks before continuing). Follow water
supply from the cold water supply valve, to
ward the sink faucet, until you reach a
coupling nut (may be at the base of the
faucet). Unscrew the coupling nut. Place
rubber washer into the plastic easy tap faucet
adapter and screw adapter onto location of
coupling nut. Hand-tighten, then tighten one
more complete turn with a wrench. Re-attach
the supply line to the adapter with the cou
pling nut. Leave the cold water off.
NOTE:
"Push-In" style fittings are designed for ease of use. Simply push the tubing in until it seats.
Give a tug on it to make sure it is secure. Insert red locking clip between fitting and collar. If you
need to remove the tubing, remove the red locking clip, hold the locking ring collar against the fitting
while pulling out the tubing. No inserts or nuts are used with the "Push-In" style fittings.
FIGURE 2 - FILTER PAK AND FAUCET INSTALLATION
Garbage Disposal
Water Supply
STEP 4 TUBING CONNECTIONS
IMPORTANT:
Fitting manufacturer requires fittings to be re-checked after system reaches
full operating pressure and temperature, Re-tighten and secure as necessary.
It is not recommended to shorten the length of any tubes during installation. This will make future
servicing easier.
A.¼" White Supply Tube on Filter Pac.
Connect the supply (white) tube firmly into the
push-in port on the side of the easy tap
adapter installed on the cold water supply
line.
OPTIONAL:
If self-piercing valve is
used, connect to valve using brass nut, tubing
support, and ferrule, (not included).
8 F1, F2, F3 FILTERPACKS 08/11 8
CAUTION:
1. When tightening easy tap, make sure the
tube to which you are attaching the easy
tap is not twisted. Use two wrenches to
hold existing tube while tightening the easy
tap adapter.
2. Examine existing cone shaped washer on
water supply tube, adjust or replace if dam-
aged or worn (not included).
3. If self-piercing valve is used instead of easy
tap, attach to hard copper tubing only. Do
not over tighten screws (see instructions on
piercing valve package, not included).
EZ Adaptor
hot
cold
Drinking Water
B. Post Filter Connection to Faucet.
Depending on the model, connect the 3/8"
blue tube from either the outlet side of the
post-filter bowl or the outlet fitting from the
10" inline post-filter cartridge to the 3/8"
push-in adapter fitting on the faucet.
STEP 5 SYSTEM START-UP PROCEDURES
Turn your sink cold water supply valve to the on position while leaving the Filter Pac ball valves
in the off position (horizontal, which is perpendicular to the valve). Check for leaks and adjust as
necessary.
A. Slowly turn Filter Pac ball valve to the on
position (blue valve vertical, which is in line with
the valve). As water enters the filter bowls and
makes its way through the filters you will hear
air escaping through the drain. This is normal.
IMPORTANT:
Check carefully for small leaks every few hours for the first few days to assure there
are no leaks. It is wise on any Filter system to inspect for leaks since the system sits unseen un-
derneath your sink and a small leak may not be detected without close inspection. Check for leaks
occasionally thereafter and make adjustments as necessary.
STEP 6 REFRIGERATOR ICEMAKER HOOK UP
A. If there is not an ice-line from the Filter Sys
tem to the refrigerator, you may choose to run
an ice-line so that your ice and water
dispenser will have filtered water.
B. Connect tube (not included) to appropriate
refrigerator connection and to a plastic "T"
Fitting (not included) spliced into the 1/4" blue
tube between the post filter and faucet. It is
recommended to install a ball valve on the
tube to the refrigerator for service and start
up purposes.
STEP 7 RECOMMENDED FILTER SERVICE LIFE
The types of filters listed below vary depending on Filter system style. The manufacturer provides
very high capacity carbon filters and replacement intervals are based on our filters. Other filters
may not have the same capacity as original factory filters and may not last as long. Water conditions
vary greatly by region and can affect filter change intervals. For filter change interval recommenda-
tions, follow the guidelines below. If in doubt, contact the manufacturer.
A. Carbon Pre-filter. These filters should be
changed at least once a year. Changing
these filters is necessary to help insure life
and water quality. Use of high capacity car-
bon block filters is recommended.
REPLACEMENT FILTERS PART NUMBERS & REPLACEMENT FREQUENCY
Filter pak
1 YEAR
1 YEAR
model
10 Micron Carbon
.5 Micron Carbon
CB #135-1210
CB05 #135-1210-1
FP1
CB #135-1210
CB05 #135-1210-1
FP2
CB #135-1210
CBLR #135-1310-1
FP3
Open faucet on the sink until the water starts
coming out. Let faucet run to drain for 3 to 5
minutes.
B. Shut off faucet and check for leaks.
IMPORTANT:
Never turn on icemaker
before Filter Pak is full of water to avoid
damaging refrigerator solenoid. If your
refrigerator has a water dispenser in the
door, upon initial start-up you will need
to depress the water supply lever 2 to 3
minutes before the water will dispense.
.................
To order replacement filters or locate a source
in your area call the factory: AmeriFlow™ Water
Systems 602-275-4188.
1 YEAR
Odor Reduction w/ scale inhibitor
10C4Scale #135-3310
F1, F2, F3 FILTERPACKS 08/11 9