DAB VS 35/150 Manuel d'installation et d'entretien - Page 9

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'entretien pour {nom_de_la_catégorie} DAB VS 35/150. DAB VS 35/150 9 pages.

DAB VS 35/150 Manuel d'installation et d'entretien
FAULTS
The pump does not start
The system is noisy
The pump is noisy
The pump starts and then stops after a short
time

TROUBLESHOOTING

POSSIBLE CAUSES
No supply voltage.
Incorrect supply voltage.
Faulty capacitor ( single phase motors).
Rotor is blocked by deposits on the rotor.
Flow rate to high.
Air in the system.
Air in the pump.
Intake pressure too low.
Dirt or scale between the rotor and the stator
lining or between the impeller and pump
body.
REMEDIES
Check the electric connections and fuses.
Check the data on the plate and apply the
corect voltage.
Change the capacitor.
Select the maximum speed and/or free with a
screwdriver.
Select a lower speed.
Bleed the system.
Bleed the pump.
Increase the intake pressure.
Check the shaft is turning freely. Remove
any dirt and/or scale.