Door Controls DC One Manuel d'installation - Page 11

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Door Controls DC One. Door Controls DC One 20 pages. Automatic sliding door retrofit drive assembly

Open Speed
OPEN SPEED
056.3%
Ranges from 5 to 100%
Adjustable in or out of program mode
Close Speed
CLOSE SPEED
020.9%
Ranges from 5 to 100%
Adjustable in or out of program mode
Open Check Speed
OPEN CHECK SPEED
012.0%
Ranges from 5 to 100%
Adjustable in or out of program mode
Close Check Speed
CLOSE CHECK SPEED
012.0%
Ranges from 5 to 100%
Adjustable in or out of program mode
Boost Speed
BOOST SPEED
030.1%
Acceleration from a stopped position to check speed
Ranges from 5 to 100%
Adjustable in or out of program mode
Open Deceleration
OPEN
DECELERATION
030
Adjusts the transition between open and open check
Higher values cause a more abrupt change between the two speeds
Ranges from 0 to 255
Adjustable in or out of program mode
Close Deceleration
CLOSE DECELERATION
030
Adjusts the transition between close and close check
Higher values cause a more abrupt change between the two speeds
Ranges from 0 to 255
Adjustable in or out of program mode
DC One V3 Installation Manual
M-0015 REV 06222017 P10
Page 9 of 15