Air Delights AutoFlush Instructions d'installation - Page 4
Parcourez en ligne ou téléchargez le pdf Instructions d'installation pour {nom_de_la_catégorie} Air Delights AutoFlush. Air Delights AutoFlush 4 pages. For urinals & toilets
ON
1
2 3
Sensor Range Reset Button
ON
1
2 3
TROUBLE SHOOTING GUIDE
PROBLEM
Green L.E.D.(light) flashes 3 times
when there are no users
Green L.E.D.(light) flashes
continuously when Object Lock Sensor is
activated by a user
Orange L.E.D.(light) flashes
Not enough water to fixture or too
much water to fixture
Valve will not operate
Valve does not shut off
Valve does not flush even after Object
Lock Sensor has been adjusted
1-800-440-5556 • 1-503-643-8224 (Fax) • 11170 SW 5th Street, Suite 100. Beaverton, O R 97005
Object Lock
Range of Detection
Distance Adjustment Screw
Modes of
Operation
Switches
Urinal Model Only
Battery LED (Yellow)
Flashing LED = Change Batteries
Object Lock Sensor
User-In-View LED (Green)
to operate per mode setting.
CAUSE
Front of Object Lock Sensor is covered or Object Lock
Sensor is set too far out,registering the opposite wall or
door as a user
AutoFlush unit is in 7 minute start up mode (when first
activated) or Sensor Range Reset Button has been
depressed
Batteries need replacing
Diaphragm damaged or valve control stop
improperly adjusted
Object Lock Sensor range set to close to AutoFlush,batteries
are dead,or water supply
is turned off
Dirt or debris preventing diaphragm from
functioning properly
Dead batteries
Use Sensor
Adjuster
Tool
Near
Urinal Model Only
ON
ON
ON
3
3
1
2
1
2
1
2
Normal
Water
Sanitary
Flushes after
Flushes before
Saver
each use
and after
each use
Flushes after
every other use
Flashes 3 Times = User acknowledged & ready
Courtesy Manual
Flush Button
(Toilet Model Only)
Allows manual activation
of flush when needed.
Remove item covering sensor or adjust Object Lock
Sensor activation distance.(See Appendix B.Adjusting
the AutoFlush)
Green L.E.D.(light) will flash only 3 times
acknowledging a user is in view after the 7 minute
start up mode
Replace batteries
Replace diaphragm and/or adjust valve control stop
Adjust Object Lock Sensor—Replace batteries—Turn
water on.
Remove dirt or debris,consult valve manufacturer' s
directions
Replace batteries.
Distance
Adjustment
-
+
Far
SWITCH
ON
ON
NO. 3
DOES
NOT
3
3
1
2
3
1
2
AFFECT
NO.'S
Stadium
Audio
1 & 2.
Flushes every
Tone sounds
3 minutes with
when batteries
continuous use
need to be
replaced
Toilet Model Only
ON
Operates
in Normal
1
Mode Only
Audio
Flushes after
Tone sounds
each use
when batteries
need to be
replaced
SOLUTION TO PROBLEM
ON
OFF
ON
OFF