Amerisolar AS-6P Manuel d'installation - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Amerisolar AS-6P. Amerisolar AS-6P 11 pages. Solar module

Worldwide Energy and Manufacturing (Nantong) Co., Limited
maintain the fire class rating, the distance between the modules frame and the roof surface
shall be at least 100mm.
Do not install the module near naked flame or flammable materials.
Do not install the module in a location where it would be immersed in water or continually
exposed to water from a sprinkler or fountain etc.

5.3 Module tilt angle

Modules connected in series should be installed at same orientation and angle. Different
orientation or angle may cause loss of output power due to difference of amount of sunlight
exposed to the module.
Modules produce the most power when they are pointed directly at the sun. For installations
where the modules are attached to a permanent structure, the modules should be tilted for
optimum winter performance. As a rule, if the system power production is adequate in winter,
it will be satisfactory during the rest of the year. Optimal tilting of the module is roughly the
same as the latitude of installation location.

5.4 Installation methods

The modules can be installed on the frame using screw mounting and clamp mounting
methods (as shown in Fig.1).
(a) Screw mounting
(b) Clamp mounting
Fig.1 The module installed with (a) screw mounting, (b) clamp mounting
(a) Screw mounting
The frame of each module has eight mounting holes used to secure the modules to the
support structure. If the wind or snow load is less than 2400Pa, you can use the four
symmetry holes close to the inner side on module frame (as shown in Fig.2). If the wind or
snow load exceeds 2400Pa, you must use all the eight mounting holes. The module frame
must be attached to a mounting rail using M8 corrosion-proof screws together with spring
washers and flat washers in eight symmetrical locations on the module.
3