Door-Gard 234 Manuel des fonctions et de la programmation - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel des fonctions et de la programmation pour {nom_de_la_catégorie} Door-Gard 234. Door-Gard 234 4 pages. Self-contained access control systems keypad
1
4. Press 7890#123456 * . If all 12 keypresses have
been verfied, the keypad will enter self test mode.
Either the LED's will flash or the sounder will beep 3
times,.then light or sound continuously for 3 seconds
(except on the mullion). If these responses do not
happen, try the test mode again and then call tech
support. Note: self test mode can be used when trou-
bleshooting a keypad in the field. If you do not get the
continuous light or sound then the memory has been
corrupt and should be re-programmed with the 46
command (see option #16).
5. Enter the master code of 1234 * . The relay will
energize. Refer to programming section to program
your keypad.
NOTE:
The keypad may be programmed in your shop or at the
installation site. Programmed information is stored in non-
volatile memory so it will not be lost if power is removed.
ACCESS CONTROL DEFAULTS
Door-Gard Self-Contained Access Control Systems
are designed for easy installation in a minimum
amount of time. The following defaults have been fac-
tory programmed.
Master Code (user 1)
Lock Release Relay will energize for 5 secs.
Keypad Active Output
Keypress Feedback
Propped door relay will energize after
Forced door relay will energize for
If defaults must be changed or additional functions
are desired, please refer to the PROGRAMMING
OPTIONS Chart after you are familiar with the
PROGRAMMING section.
PROGRAMMING
1. Enter programming mode
Press 99 # (master code) *
ly
1234 *
Off
On
30 secs.
10 secs.
1
Yellow LED
2
Flashes slow-
2
2. To Change master code
Press 1 # (new master code) *
Press (new master code) *
If main relay time must be changed,
substitute option 2 from Programming
Options chart for step 2 above.
3. To Add/change second code
Press 2 # (new user code) *
Press (new user code) *
4. To Add/change third code
Press 3 # (new user code) *
Press (new user code) *
5. Up to 120 codes may be added in this fashion
6. Exit programming mode
Press *
NOTE:
•
Door•Gard Self-Contained Access Control
1
Systems are factory programmed with a
master code of 1234 *.
•
Some Door•Gard products contain a sounder in
2
place of the yellow LED. In these products the
flashing is replaced by a beeping.
•
3
The master code is always user 1.
• The master code allows access to the
programming mode & activates the main relay.
• All codes must be followed by the *.
• Codes may be from 1-6 digits in length, and digits
may be repeated.
• If the master code is forgotten or does not seem to
be working, momentarily remove the programming
jumper (or push SW1 on the
diagram for location) to enter programming mode
and go to option #16 and default keypad.
• If the yellow LED lights (or sounder sounds) solid
while in programming mode an error has occurred.
Press * to clear (yellow LED should flash or sounder
sound) and start over from step 2 or 3 above.
PROGRAMMING OPTIONS CHART
If the pre-programmed default values must be changed
or additional functions are desired, the following
options may be programmed
3
Flashes fast
Flashes slowly
Flashes fast
Flashes slowly
Flashes fast
Flashes slowly
Out
style, see wiring
SE