Door-Gard Wiegand 272i Instructions de programmation et d'utilisation - Page 3

Parcourez en ligne ou téléchargez le pdf Instructions de programmation et d'utilisation pour {nom_de_la_catégorie} Door-Gard Wiegand 272i. Door-Gard Wiegand 272i 4 pages. Wiegand 272 series

3
PROGRAMMING OPTIONS CHART
If the pre-programmed default values must be changed
or additional functions are desired, the following options may be programmed.
1. Enter programming mode
2. Auto entry on (no * required)
3. Auto entry off ( * required)
4. Sounder feedback on keypress
5. Sounder feedback on keypress off
6. LED options
Green LED activates when line is pulled low
Green LED activates when line is pulled high
Red LED activates when line is pulled low
Red LED activates when line is pulled high
Green LED enable
Green LED disabled
Red LED enable
Red LED disabled
Yellow LED feedback on keypress enabled
Yellow LED feedback on keypress disabled
7. Erase keypad memory and reset defaults
8. Change master code
9. Select Wiegand Format (from table below)
10.Set Site Number
11.Set Group ID
12.Exit Program Mode
The Wiegand format, group ID, and site number is specified by the host access control system and should be deter-
mined prior to programming your DoorwGard Wiegand keypad.
There are 8 different wiegand formats supported by the DoorwGard Wiegand Series keypads. The wiegand format is
set through command 63 and must be selected prior to programming the Site Number or Group ID. The user can set up
the Site Number through command 64. The exact range for a valid Site Number is determined by the Wiegand format
which is why it must be selected first.
Some of the Wiegand formats have a Group ID embedded in their frames. Command 65 is used to set up the Group
IDs. As with the Site Numbers, the valid ranges for Group ID entries are based on the Wiegand format. If the yellow led
glows steady after entering this command, there are two possible problems. Either the current format does not support
Group IDs or the ID entered is invalid. A table showing the valid ranges for Site Numbers and Group IDs based on the
various formats is presented below.
Format
1
2
3
4
5
6
7
8
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Format Table
Frame Size
PINs
26 bits
65536
28 bits
32768
29 bits
524288
30 bits
65536
31 bits
65536
32 bits
65536
36 bits
1048576
29 bits
524288
99 # (master code) *
30 # 2 # 1 # * *
30 # 2 # 0 # * *
30 # 0 # 1 # * *
30 # 0 # 0 # * *
31 # 4 # 0 # * *
31 # 4 # 1 # * *
31 # 2 # 0 # * *
31 # 2 # 1 # * *
31 # 3 # 1 # * *
31 # 3 # 0 # * *
31 # 1 # 1 # * *
31 # 1 # 0 # * *
31 # 0 # 1 # * *
31 # 0 # 0 # * *
46 # 00000 # 00000 # * *
1 # code * code *
63 # 0 # format # * *
64 # 0 # (site number) # * *
65 # 0 # (group id number) # * *
*
Sites
Groups
256
N/A
256
N/A
256
N/A
256
16
256
32
2048
64
256
N/A
256
N/A
6057130 REV 1.1