6.
WARNINGS
6.1.
Skilled technical personnel
It is advisable that installation be carried out by skilled personnel in
possession of the technical qualifications required by the specific
legislation in force.
The term skilled personnel means persons whose training, experience and instruction, as well
as their knowledge of the respective standards and requirements for accident prevention and
working conditions, have been approved by the person in charge of plant safety, authorizing
them to perform all the necessary activities, during which they are able to recognize and avoid
all dangers. (Definition for technical personnel IEC 364).
6.2.
Safety
-
Use is allowed only if the electric system is in possession of safety precautions in accordance with the
regulations in force in the country where the product is installed (for Italy, CEI 64/2).
-
The pump must never be allowed to run dry.
-
The pump cannot be used in swimming pools, ponds or tanks in which people are present.
-
The pump is provided with a hook to which a rope or cable may be connected to lower the machine into
working position. The pumps must never be carried, lifted or made to operate hanging from their
power cables.
-
Qualified personnel must be employed for all electrical repairs which, if badly carried out, could cause
damage and accidents.
6.3.
Checking rotation of the PULSAR motor shaft.
If the motor does not work and the shaft does not turn when the switch and/or float is operated, you must
check that the moving parts are turning freely.
To do this:
-
Completely disconnect the pump from the power mains.
-
Place the pump in a horizontal position.
-
Remover the filter cover, slackening the three screws with a screwdriver.
-
Using a size 13 box spanner, slacken the self-locking nut and turn the motor shaft in a clockwise
direction.
-
Replace the filter cover and install the pump as indicated in chapter 7.
6.4.
Checking rotation of the PULSAR DRY motor shaft.
If the motor does not work and the shaft does not turn when you switch on the pump, you must check that the
moving parts are turning freely.
To do this:
-
Completely disconnect the electropump from the electric power mains.
-
Place the electropump in horizontal position.
-
Remove the steel base, slackening the eight screws and nuts with a spanner.
-
Using a size 13 hexagonal box spanner, adjust the self-locking nut and turn the motor shaft in a
clockwise direction.
-
Replace the steel base and install the electropump as indicated in chapter 7.
6.5.
Cleaning the PULSAR filter.
To clean the filter, proceed as follows:
-
Place the pump in a horizontal position.
-
Remover the filter cover, slackening the three screws with a screwdriver.
-
Clean the inside of the filter, removing any particles that may have been sucked in.
-
Check that the various filter slots are free from foreign bodies.
-
Replace the filter cover and install the pump as indicated in chapter 7.
6.6.
Responsibility
The Manufacturer does not vouch for correct operation of the pumps if they are
tampered with or modified, run outside the recommended work range or in contrast with
the other instructions given in this manual.
The Manufacturer declines all responsibility for possible errors in this instructions
manual, if due to misprints or errors in copying. The company reserves the right to make
any modifications to products that it may consider necessary or useful, without affecting
the essential characteristics.
ENGLISH
21