STEP 3: DOWELS AND SCREWS
You can mount the device permanently on a wall or ceiling using appropriate
screws. Please skip this step if you do not want to mount the device permanently.
Press the drilling template of the device against the wall or ceiling at the
desired installation site and mark the boreholes with a pencil. Remove the
drilling template again. Ensure that no cables are to be found in the wall
or ceiling behind the boreholes.
If the wall of the house is not made of wood, you should drill dowel holes
5 mm in diameter in the wall according to the drilling template and then place
the dowels provided into the boreholes. If the wall of the house is made of
wood, dowels are normally not required. There are special dowels for assembling
the device on an insulating wall, e.g. Fischer insulating dowels. Please check with
your insulating material manufacturer regarding which dowels they recommend.
Press the device on the wall or ceiling, so you can see the boreholes in the wall/
ceiling through the screw holes of the device. Use the Phillips countersunk head
screws provided to position it in the dowels or on the wall to fix the device on
the wall/ceiling.
STEP 4: INSTALLATION
Connect the network cable coming from your Internet to the RJ45 jack „LAN
IN" of the device. Then connect a second network cable to the RJ45 jack
„POE + DATA OUT" of the device. Connect the spare end of the network cable
connected to the RJ45 jack „POE + DATA OUT" to the product you would
like to establish a PoE and network data connection with, e.g. a DoorBird IP
Video Door Station, DoorBird 2-Wire Ethernet PoE Converter (Sender) or an
IP Camera.
A Cat.5 network cable with RJ45 plug or better must be used to connect to
the „LAN IN" and „POE + DATA OUT" jacks of the device.
Connect the 5.5 mm DC plug of the Power supply unit (mains adaptor)
supplied with the device into the jack „15 VDC IN" of the device. Do not plug
the Power supply unit itself into a wall socket yet.
STEP 5: ACTIVATING THE DEVICES
Switch on the power leading to the assembly location again. Then plug the
Power supply unit (mains adaptor) of the device into a wall socket.