INSTALLATION

Remove the back cover from the unit
Drill 2 holes (A,C) on the wall for the screws and one hole for the cable
Knock the supplied rubber bungs to the screw holes (A,C)
Fix the back cover firmly on the wall with 4 flat head screws
Thread the cable through the cable hole (B)
Attach the unit to the back cover
Wiring cable
Wire Insulation Colour
Red
Black
Grey & Black
Blue
White
Green
Yellow
Blue & Black
White & Black
Green & Black
Yellow & Black
Grey
Brown
Function
AC & DC
AC & DC
GND
NO1
COM1
NC1
OPEN1
Advanced Input and Output Features – Relay 2
NO2
COM2
NC2
OPEN2
Alarm -
D_IN
Notes
12-24V DC / 12-18V AC Regulated Power Input
12-24V DC / 12-18V AC Regulated Power Input
Negative Pole
Normally Open Relay 1 output
Common Connection for Relay 1 Output
Normally Closed Relay 1 Output
Request to Exit input 1
Normally Open Relay 2 Output
Common Connection for Relay 2 Output
Normally Closed Relay 2 Output
Request to Exit input 2
Alarm Negative
Door Status Detecting