INSTALLATION
7.2 Mounting via the chain operator
•
Additional accessories for installation can be purchased separately.
•
Mount the large sprocket on the gate shaft end.
•
Fix the bracket on the wall according to the length of the chain using dowels.
•
Secure the operator on the bracket using 4 bolts M10. Tension the chain, having adjusted the position of the operator.
Mounting options
Direct transmission 1:1
Gear ratio 1:1,5
8. Wiring
Very important: Always disconnect power before starting work with the control plate (connection, maintenance).
•
Connect the ground wire to the suitable terminal on the electric operator housing.
•
Always route the signal wires of control and safety devices separately from the supply cable 230V and power leads of
electric motors using separate flutes and tubes.
The cable wires must be protected from the contact with any rough and sharp parts.
In order to protect electric elements from moisture, tighten the waterproofing reducing coupling of the cable input by turning the plastic
nut.
1. Selection of supply voltage (terminal block X7)
To select voltage 220V, connect 'CO' and '400V'
Voltage: 220V
Jumper
Voltage: 220V
2. Connection of supply voltage (terminal block X5)
Connect voltage 220V to terminals 'L1', 'L3'.
Jumper
Connect voltage 380V to terminals 'L1', 'L2', 'L3'.
Voltage: 220V
Voltage: 220V
Voltage: 220V
Jumper
Capacitor
Motor 220V
Capacitor
Voltage: 220V
Motor 220V
6
Motor 220V
Torque (Nm)
120
180
Voltage: 380V
Jumper
Voltage: 380V
Jumper
Voltage: 380V
Voltage: 380V
Jumper
Voltage: 380V
3�motor 380V
Voltage: 380V
3�motor 380V
O PERATO R S HA F T-1 2 0 I N STA L L AT IO N AND O PE RAT ING MANU AL
Capacitor
3�motor 380V
Shaft speed (rpm)
22
15
Shaft
Large gear wheel
Chain
Small gear wheel
The optional device is not included in the
standard package.
Voltage: 220V
Jumper
3. Motor (terminal block X4)
Connect motor to terminals 'U', 'V' and 'W'.
380V motor: max. operating current < 9A, wattage ≤ 4 kW
Voltage: 220V
220V motor: max. operating current < 2.4A, wattage ≤ 2.4 kW
Close
Capacitor
Close
Motor 220V
4. End switches (terminal block X10)
Connect end switch wires 'OP' (opening switch), 'CL' (closing
switch) and 'GND' (common wire).
Close
Open
Maximum amount of gate shaft
rotations
18
12
Voltage: 380V
Jumper
Voltage: 380V
Open
Common
Open
Common
3�motor 380V
Common
Clo