«If the time to make service is coming, the operation display is blocked. In this case, «Ser» permanently displayed and service
LED lights. Reset flag service main- tenance performed in the extended menu. The same applies to the error indication; if during
operation occurred exceptional situation, the de-energizing the system to the display will show a message «ErX», where X - number
error. Number of the last emergency case can be viewed in the extended menu.»
6.2. ENTERING TO THE PROGRAMMING MODE
To enter the programming mode, switch on the control unit, turning the main switch to position «I». Make sure that the control
unit power indicator lights, press briefly 'Down' button, then simultaneously press the "UP" button and "Auto" button within five
seconds. «UH *» symbol in digital display means that you are in the programming mode (* - Flashing). Programming menu DCUH-
2 shown in Table 2.1.»
Table 2.1.
PARAMETER
Parameter value 1-9 (3-11sec.) Default value 7 sec.
1. «UH»
Parameter value 1-9 (5-21sec.) Default value 13 sec.
2. «UC»
Parameter value 1-9 (2,5-6,5sec.) Default value 4,5 sec.
3. «Hd»
4. «AF»
5. «Ar»
6. «CXX»
7. «SXX»
8. «EXX»
9. «rS»(1)
Programming menu DCUH-3 shown in Table 2.2.
Table 2.2.
PARAMETER
Parameter value 1-9 (3-11sec.) Default value 7 sec.
1. «UH»
Parameter value 1-9 (5-21sec.) Default value 13 sec.
2. «UC»
Parameter value 1-9 (2,5-6,5sec.) Default value 4,5 sec.
3. «Hd»
4. «AF»
5. «dL»
6. «Ar»
7. «CXX»
8. «SXX»
9. «EXX»
10. «SL»
Parameter value 1-9 (17-35sec.) Default value 25 sec.
11. «Sb»
Parameter value 1-9 (2-18sec.) Default value 10 sec.
12. «Gd»
13. «rS»(1)
8
RANGE
Changing by 1 = 1 sec.
Changing by 1 = 2 sec.
Changing by 1 = 0,5 sec.
Parameter value 1-9
(Y/n), default value - «Y»
(0-99)
(0-99)
(0-99)
(Y/n), default value - «n»
Range
Changing by 1 = 1 sec.
Changing by 1 = 2 sec.
Changing by 1 = 0,5 sec.
Parameter value 1-9
(Y/n), default value - «n»
(Y/n), default value - «Y»
(0-99)
(0-99)
(0-99)
(Y/n), default value - «Y»
Changing by 1 = 2 sec.
Changing by 1 = 2 sec.
(Y/n), default value - «n»
DESCRIPTION
Lifting time in parking mode
Lowering time in parking mode
Lifting time of last part of parking
"Threshold stop, apply to the action: ""Lifting platform"""
Y = Parking mode On. N = parking mode OFF
Cycle counter /1000
Service counter
"The indicator last emergency situation:
«E00» - emergency for the entire period of operation did not occur;
«E01» - an error of use;
«E03» - a short circuit in the motor winding in powerpack;
«E04» - a short circuit on the control board and display."
Reset of service mode
Description
Lifting time in parking mode
Lowering time in parking mode
Time of the apparel pulling in
"Threshold stop, apply to the action: ""Lifting platform"""
Automatic door closing
Y = Parking mode On. N = parking mode OFF
Cycle counter /1000
Service counter
"The indicator last emergency situation:
«E00» - emergency for the entire period of operation did not occur;
«E01» - an error of use;
«E03» - a short circuit in the motor winding in powerpack;
«E04» - a short circuit on the control board and display."
Y = Inflatable dock shleter = On. N = Inflatable dock shleter = Off
Deflating time
Time of door closing
Reset of service mode
PROGRAMMING