DoorKing 9000 Series Manuel de démarrage rapide

Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} DoorKing 9000 Series. DoorKing 9000 Series 2 pages. High voltage kit
Également pour DoorKing 9000 Series : Manuel (5 pages), Manuel de démarrage rapide (2 pages)

DoorKing 9000 Series Manuel de démarrage rapide
QUICKSTART "BASIC" GUIDELINES FOR MODEL 9000 - FRONT INSTALLATION MOUNTED ON A CONCRETE PAD "FULL OPEN"
Adjustment of Limit Switches
Adjust the 2 limit nuts by depressing the lock plate and spin nuts to
desired open and closed gate positions. After adjusting, make sure
the lock-plate is engaged in the slots on the limit-nuts to prevent
them from rotating. See manual for more information.
Chain Adjustment
Adjust the chain nuts to tighten the chain. The chain
should sag no more than one (1) inch per 10 feet of
chain travel. Do not over tighten the chain.
Chain brackets MUST be
mounted so the chain
remains the same height
as it is on the idler wheels!
1
i t c h
S w
N
i n O
n .
i t i o
p o s
1
S W
n g
e n i
i o n
O p
e c t
D i r
Two 115 VAC
Convenience Outlets
For access control and safety device AC power.
L o c
R a
d i o
R e
c e i
C
v e r
B
r
I d l e
B
e e l
W h
l
h e e
o n
r W
s i t i
I d l e
P o
T o p
t e r
C e n
o n
s i t i
Reset
P o
m
t t o
B o
o n
s i t i
P o
C o
n c r
M U
e t e
S T
p a
b e
d
l e v
e l !
4 )
C o
p
e (
L o o
i t
U s
n d u
n c
t s u
C o
( N o
r e t
e
r
w e
P a
P o
i t
A C
d
n d u
C o
B e l
d e t
c o d
C h
a i n
S W
B r a
k P
c k e
l a t e
t
D
E
A
DO NOT
power up and cycle the
operator until the "DIP-Switches"
and the "Limit Switches" have
r
w e
P o
been adjusted. Damage could
occur to the gate and operator.
Chain, Conduit Area and Concrete
4" minimum
space
between the
gate and
r s
c h o
operator
A n
u m
e v e
d .
n i m
S l e
chassis.
u n
m i
2 "
g r o
4 "
" x
o v e
3 / 8
) .
a b
i s
i n g
l i e d
a d
u i l d
p p
t e p
a l b
c r e
l o c
.
c o n
e d )
a n d
e n d
t h e
o n s
o f
m m
d i t i
t h
e c o
d e p
c o n
e r
u n d
r e t
o i l
o n c
g r o
y s
d c
d b
o w
i n e
r c e
i n f o
e r m
( r e
Warning Signs
e s
Permanently mount signs on BOTH sides of the
gate area and make sure they are easily visible.
Copyright 2019 DoorKing
®
, Inc. All rights reserved.
1
i t c h
UL 325 August
S w
Model 9000 is intended for
F F
2018 Standard
i n O
.
o n
installation only on sliding
s i t i
p o
gates used for vehicles.
n g
e n i
i o n
O p
Pedestrians must be supplied with
e c t
D i r
a separate access opening.
1
For complete safety, installation
and adjustment of operator
instructions, please refer to the
Series 9000 Installation/Owner's
manual.
DIP-Switches
Typical Single Operator Settings
1.
Opening Direction
(See Illustration)
2. OFF
3.
ON
Auto-Close Timer
4.
ON
TIME
5. OFF
DELAY
6. OFF
E
7. OFF
D
8. OFF
1 23
SW 1
Adjust
1. OFF
1 to 23 sec.
2. OFF
(See reverse side for
3.
ON
more information).
4. OFF
SW 2
24"
Operator Chassis
4"
3.5"
13.5"
Center
24"
of
Conduit Area
4.5"
concrete
pad
Concrete Pad
Operator and chain
Entrapment Protection must be provided for the gate
MUST be parallel to gate!
system where the risk of entrapment or obstruction exists.
The operator will NOT run without one or more monitored
type B1 or B2 external entrapment protection devices in
EACH direction of gate travel (minimum of 2 external
Chain bracket MUST line
devices required). See manual for more information.
up with chain idler wheels!
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
High Voltage Connection
GATE OPERATOR MUST BE PROPERLY GROUNDED!!
Tip: It is recommended that a surge suppressor be
installed on the input high voltage power line.
DANGER
115 VAC
HIGH VOLTAGE
A
Note: "Optional" High
Voltage Kit black and
white wires connect
the same as shown.
See High Voltage Kit
instruction sheet for
more information.
Input Power Line:
White - Neutral
Chassis
Ground
Black - 115 VAC Hot
Green - Chassis Ground
Loop Detectors
B
Not included - Refer to the Installation/Owner's manual
for more information about DoorKing's Plug-In loop
detectors. DoorKing highly recommends that loops and
loop detectors are installed with this slide gate operator.
DoorKing offers a free "Loop and Loop-Detectors
Information Manual" PDF located at DoorKing's web
site for more information. www.doorking.com
Radio Receiver
C
Not included - Refer to a specific Radio Receiver
Manual (available from www.doorking.com) for more
information on radio receivers and antenna installation.
(See reverse side for wiring)
9000-066-K-2-19