• Check that the pump is stable and leveled.
• The hydraulic circuit should be drained and not contain any foreign bodies.
• The lid of the pre-filter basket must be properly closed (manually) and its seal clean and
properly in place.
• Check that the valves are open.
• As the pump is self-priming, the pre-filter must be filled with water before starting it up
for the first time in order to facilitate the process. (FIGURE 7).
• The pump has a priming capacity of up to 1.5 meters above the water level of the pool at
sea level (if the hydraulic circuit is properly sealed).
• Start the pump electrically.
• Bleed the air that may have built up in the filtration circuit using the drainage, which is
usually on the filter (see the pool filter manual).
• Check that there are no leaks in the hydraulic circuit.
• Check that the motor is turning in the right direction (look at the fan located at the back of
the motor). (FIGURE 8).
12
PRIMING
FIGURE 7
FIGURE 8
Installation and general maintenance manual
RIGHT
WRONG
FAN COVER
- SELF-PRIMING POOL PUMPS