Astrapool E35 Manuel d'installation et d'utilisation - Page 5
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Astrapool E35. Astrapool E35 10 pages. Salt chlorinator
- 1. Operating Instructions
- 2. Table of Contents
- 3. General Overview
- 4. Chlorinator Control Installation
- 5. Cell Installation
- 6. Pool Preparation
- 7. Programming
- 8. Chlorine Output
- 9. Setting the Right Chlorine Output and Filtration Time
- 10. Chlorinator Maintenance and Troubleshooting
- 11. Maintenance of Your Chlorinator
- 12. Troubleshooting
- 13. Warranty
PROGRAMMING
Setting Current Time/Day
Select Off
(a) Press the MENU button and screen should display CLK. Press ENTER
(b) Press ENTER and the hour digit will flash. Use up and down arrows to adjust.
(c) Press ENTER to change to minutes and set.
(d) Press ENTER and select AM or PM
(e) Press MENU to save
Setting Timers
Your Chlorinator has 2 timers enabling you to set different periods in which your chlorinator/pump will operate. Timers are
set by entering a start time and an off time. To set timers, do the following:
(a) Press the MENU button twice and screen should display TMR. Press ENTER
(b) Use up and down arrows to adjust start time for TIMER1. Press ENTER
(c) Use up and down arrows to adjust the off time for TIMER 1. Press ENTER.
(d) Repeat for TIMER 2
Programming Recommendations
AstralPool recommend that you use two timers, one for the morning and one for the evening and typically for periods of 2-5
hours for each. Your chlorinator is most effective if running in the early morning or evening when it is cooler (strong sunlight
consumes more chlorine). As a factory default, the control is set to come on at 08:00am and 04:00pm both for periods of 4
hours.
CHLORINE OUTPUT
To adjust the chlorine output:
(a)
Use Increase/Decrease arrows for setting the chlorine output level of the chlorinator. The Chlorinator output can
be set from levels 1 through to 8.
(b)
Chlorine Output display shows the level set
USER OPERATION
The user mode buttons enable you to select Pool or Spa mode and to manually control the Chlorinator/Pump. Functions
are as follows:
POOL MODE:
(a)
Auto - Running
Manual -Running
Manual - Stopped
Maximum efficiency will be achieved from you chlorinator at the following levels:
Water temperature 15 Degrees – Salt level required is 6000 ppm
Water Temperature 25 Degrees – Salt level required is 4,100 ppm
FAULT CODES
The User Display can indicate the following fault codes;
NO F – No flow indication
LO S – Low salt indication
Refer to troubleshooting table at the end of this manual for actions to correct these errors.
INST 363 E Series Salt Chlorinator V05.17
The Chlorinator/Pump will run according to how you have set the timers
The Chlorinator/Pump will run continuously.
The Chlorinator/Pump will stay off continuously.
5