Astrapool Viron Series Manuel d'installation et d'utilisation - Page 11

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Astrapool Viron Series. Astrapool Viron Series 14 pages. Salt chlorinator

7.0 Swimming Pool Applications and the use of Cyanuric Acid

USE OF A SUN SCREEN CHEMICAL (CYANURIC ACID) FOR OUTDOOR POOLS IS RECOMMENDED.
CHECK WITH YOUR LOCAL POOL SHOP AND USE THE CORRECT DOSAGE. ENSURE YOUR POOL WATER IS WELL
BALANCED WITH THE CORRECT pH, TDS, TA AND STABILISER LEVELS AND FREE FROM PHOSPHATES.
8.0 Fault Indication and trouble shooting
Fault Indication
Potential Cause
No Flow
Pump turned off/disconnected or valves
closed
Sense wire disconnected from cell
Low salt
Salt level in pool has dropped too low
Pool water temperature is low
Cell has failed
Display blank
No Power to Controller
Fuse blown
Low/No chlorine
Cables not connected to cell
production
Timer period too short
Chlorine output level too low
Filter needs backwashing
Pool stabiliser too low
Salt level too low
Water Temperature below 15 deg
Excessive Salt Level (Above 10,000 ppm)
Clock loses time
Battery life expired
when mains power
removed
Inst305 - Viron Series Chlorinator Instructions V05-17
Remedy
Ensure valves/pump on
Connect sense wire to cell
See section 7.5 above
Increase salt level or raise water
temperature
Call a technician
Plug in controller and ensure
mains power available
Call a technician
Connect cables
Increase timer period
Increase chlorine output
Backwash filter
Get Stabiliser between 30 and
60 ppm
Increase salt to above 4000ppm
Increase water temperature or
salt level
Chlorinator cuts out on
overload, reduce salt level to
4000 ppm
Call a technician
11