General Information
1. Please check that all components are in the box prior to installation of this
product. Before starting the installation of this product, ensure that the site
conditions are suitable for installation of this product. The hot supply connection
is through the flexible inlet tail nearest the spout of the T301 tap, identified with
a red mark.
2. We recommend that isolation valves (not supplied) must be fitted as close
as is practicable to the water supply inlets of the T301 mixing valve for
maintenance and servicing purposes.
3. Care must be taken during installation to prevent any risk of damage.
4. This product is intended to be installed in a single or twin tap hole wash hand
basin. The hole in the basin must be a minimum of 30mm up to a maximum of
36 mm diameter, with a basin thickness of 30mm maximum.
5. The T301 should be positioned for easy access during use and maintenance.
All routine maintenance procedures can be conducted with the T301 in place.
6. Pipework dead-legs should be kept to a minimum.
7. Supply pipework layout should be arranged to minimise the effect of hydraulic
restriction or other outlet usage upon the dynamic pressures at the T301 inlets.
Recommended minimum supply line pipe diameter is 1/2" or 15mm.
8. Inlet threaded joint connections should be made with PTFE tape or liquid sealant.
Do no use oil-based, non-setting jointing compounds.
9. To eliminate pipe debris it is essential that supply pipes are thoroughly flushed
through before connection to the T301.
Installation must be carried out in accordance with these
instructions, and must be conducted by designated, qualified
and competent personnel.
5