Flying Industry Development 00200261 Manuel rapide - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel rapide pour {nom_de_la_catégorie} Flying Industry Development 00200261. Flying Industry Development 00200261 3 pages. Rf wireless receiver
Setting control mode Toggle: Only connect Jumper-2.
Control mode Toggle: Press -> On; Press again -> Off.
Press button 1: Turn on the relay (connect B and C, disconnect A and B), the lamp 1 is on.
Press button 1 again: Turn off the relay (disconnect B and C, connect A and B), the lamp 1 is off
Setting control mode Momentary: Only connect Jumper-1.
Control mode Momentary: Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on the relay (connect B and C, disconnect A and B), the lamp 1 is on.
Release button 1: Turn off the relay (disconnect B and C, connect A and B), the lamp 1 is off
Setting control mode Latched: Disconnect Jumper-1 and Jumper-2.
Control mode Latched: Press -> On, other relays Off; Press another button -> Off.
Press button 1: Turn on the relay (connect B and C, disconnect A and B), the lamp 1 is on.
Press button 2: Turn off the relay (disconnect B and C, connect A and B), the lamp 1 is off
How to pair the transmitter to the receiver:
1) Press the learning button of receiver for 1- 2 seconds; signal LED on the receiver is on. The receiver enters into status of LEARNING.
2) Press any one button on transmitter. If signal LED flashes quickly 15 times and turns off, it means learning is successful.
3) When receiver is in the status of LEARNING, press again the button of receiver, signal LED turns off, learning process will be discontinued.
4) The receiver can learn several remote controls with different codes.
Delete all transmitters:
We have learned remote control to the receiver. If you don't want the receiver to work with the remote control, you can delete all codes of remote
controls, which are stored in the receiver.
Operation: Press and hold the button of receiver until signal LED flashes slowly; release the button, LED keeps slow flash. That means all stored
codes have been deleted successfully.
SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com
E-Mail: [email protected]