Reported Fault
Pump does
not activate
when shower is
turned on.
Pump flow rate
too fast/too
slow or delay
time/run-on
time too long/
too short.
Continued...
Order: 01905 823 299
|
orders.akw-ltd.co.uk
Possible Causes
flow switch(s)/sensor(s)
not connected properly.
Note: Status leD on the
controller will flash when
receiving a valid flow signal.
Incorrect controller setup.
flow switch(s) blocked.
Insufficient flow rate to
activate flow switch.
Connection from controller
to pump broken.
faulty pump motor.
Incorrect controller
setting(s).
Troubleshooting
Checks/Actions
External switch/sensor installation
Check switch/sensor installation and integrity
of wiring.
Electric Shower with integral switch/sensor
Check integrity of wiring between shower and
controller.
Refer to shower manual for correct settings.
Electric Shower wireless connection
Refer to shower manual for correct settings
and installation of wireless module.
Refer to controller manual for correct settings
and installation of wireless module.
Refer to controller manual and confirm menu
settings.
Check filter is fitted before flow switch and
that neither filter nor switch is blocked.
Check for minimum flow rate of 2lpm (electric
shower) / 4lpm (mixer shower).
Check wiring integrity.
Replace unit.
Refer to controller manual for correct settings.