Astro-Gadget DobsonDream Manuel de l'utilisateur - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Astro-Gadget DobsonDream. Astro-Gadget DobsonDream 8 pages. Push-to dsc controller
Also, using the DobsonDream setting panel utility, you can check and compare the estimated
number of steps / pulses per rotation of the telescope axis with the actual number for
encoders installed radially. To do this, go to continuous reading of the encoders by clicking
the Continuous reading button, and clicking Reset by resetting the reading to zero, as in
photo 5.
Make marks with a thin marker on the disks of the mount axes to count the full revolution, as
in photo 6.
If there is no possibility to rotate the axis for a complete revolution, make marks for 1/2 or
1/4 turn. Rotate the telescope axis from the zero mark to the mark, for example, 1/2 turn. In
this case, if the estimated number of steps / pulses per revolution is 10,000, the
DobsonDream setting panel should show 5000 steps / pulses.
DobsonDream is ready for use.
Photo 5
Photo 6