Air Gunsa AZ3 HTE2 AV Manuel d'instruction

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Air Gunsa AZ3 HTE2 AV. Air Gunsa AZ3 HTE2 AV 17 pages. Spray gun
Également pour Air Gunsa AZ3 HTE2 AV : Manuel d'instruction (4 pages), Manuel d'instruction (9 pages)

Air Gunsa AZ3 HTE2 AV Manuel d'instruction
Instruction Manual
SPRAY GUN AZ3 HTE2, AZ3 HTE2 AV, AZ3 HTE2 P AV, AZ3 HTE2 HVLP
Before use, adjustment or maintenance, it is important
GB
to read this instruction manual very carefully. This manual
must be stored in a safe place for any future reference.
This AIR GUNSA spray guns kit complies to
ATEX regulations 94/9/EC, protection level:
II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be divert-
ed to the ground via the conductive air hose as stipulated.
ALWAYS observe WARNINGS and CAUTIONS in this
instruction manual.

TECHNICAL SPECIFICATIONS

Max. working air pressure:
7.0 bar (100 PSI)
Noise Level (LAeqT)*:
77.6 dB (A)
Max. Temperature range:
5 ~ 40 °C
* Measuring point: 1m backwards from gun, 1.6m height
Model
Nozzle
Air cap Air pressure Fluid
Orifice
set Mark at gun inlet output consumption
Ø mm (in)
AZ3 HTE2 / AZ3 HTE2 AV Gravity feed
HTE 2 1.0
1.0 (0.039)
10-15
HTE 2 1.3
1.3 (0.051)
HTE
HTE 2 1.5
1.5 (0.059)
HTE 2 1.8
1.8 (0.070)
18-20
HTE
HTE 2 2.0
2.0 (0.079)
HTE 2 2.5
2.5 (0.098) 25 HTE
HTE 2 2.8
2.8 (0.110)
28-30
HTE
HTE 2 3.0
3.0 (0.118)
HTE 2 3.5
3.5 (0.138) 35 HTE
AZ3 HTE2 P AV Model with Pressurized Cup
HTE 2 P AV 1.3 1.3 (0.051)
10-15
HTE
HTE 2 P AV 1.5 1.5 (0.059)
HTE 2 P AV 1.8 1.8 (0.070)
18-20
HTE
HTE 2 P AV 2.0 2.0 (0.079)
HTE 2 P AV 2.5 2.5 (0.098) 25 HTE
The Anest Iwata AirGunsa AZ3 HTE2 HVLP spray gun follows all compliant HVLP man-
dates. The maximum inlet pressure of 30psi (2,0 bar) to achieve 10psi (0,7 bar) air cap
pressure measured dynamically at he center of the air cap follows HVLP standards
worldwide.
HTE 2 HVLP
1.3 (0.051)
HTE 2 HVLP
1.5 (0.059)
HVLP
HTE 2 HVLP
1.8 (0.070)
HTE 2 HVLP
2.0 (0.079)
SAFETY WARNING
FIRE AND EXPLOSION
1. Never use the following HALOGENATED HYDROCARBON SOLVENTS:
which can cause cracks or dissolution of gun body (aluminium) due to
chemical reaction. UNSUITABLE SOLVENTS: methyl chloride, dichloro-
methane, 1.2-dichloroethane, carbon tetrachloride, trichloroethylene,
1.1.1-trichloroethane
2. Sparks and open flames are strictly prohibited. Paints can be highly
flammable and can cause fire.Do not expose to open flames, electrical
goods, cigarettes etc.
3. Securely ground spray gun using conductive air hose. (Less than 1MΩ)
Always ensure that the spray gun is earthed correctly.
Manufactured by: AIR GUNSA s.r.l, 46 Corso Vigevano 10155 Torino - Italy
HEADQUARTERS: ANEST IWATA Corporation
3176, Shinyoshida-cho, Kohoku-ku - Yokohama, 223-8501 JAPAN
Air connection:
G 1/4"M
Fluid connection:
G 1/4"F
Weight g (lbs)**:
517 (1.14)
** Weight without cup..
Air
Pattern
Width
bar (PSI) ml/min Nl/min (cfm) mm (in)
80
200 (7.06)
180 (7.08)
140
200 (7.06)
240 (9.44)
2.0 (29)
160
200 (7.06)
260 (10.23)
250
215 (7.59)
300 (11.81)
300
215 (7.59)
340 (13.38)
450
280 (9.89)
360 (14.17)
540
300 (10.59) 380 (14.96)
3.0 (44)
560
300 (10.59) 400 (15.74)
600
300 (10.59) 420 (16.53)
140
200 (7.06)
240 (9.44)
160
200 (7.06)
260 (10.23)
2.0 (29)
250
215 (7.59)
300 (11.81)
300
215 (7.59)
340 (13.38)
3.0 (44)
450
280 (9.89)
360 (14.17)
150
280 (11.0)
2.0 (30 psi)
185
290 (11.4)
340 (12.0)
Air cap press.
215
340 (13.4)
0.7 bar (10psi)
240
360 (14.2)
PROTECTION OF HUMAN BODY
1. Use in a well-ventilated site, using a spray booth.
Poor ventilation can cause organic solvent poisoning and fire.
2. Always wear protective gear (safety glasses, mask, gloves) to avoid
inflammation of eyes and skin.
In case of any physical discomfort, immediately seek medical advice.
3. Noise level can exceed 85dB(A), wear earplugs if necessary.
4. Pulling the trigger many times during operation, may cause carpal
tunnel syndrome. Always rest, in case of tiredness.
IMPROPER USE
1. Never point gun towards people or animals.
2. Never exceed maximum working pressure or maximum operating
Temperature
3. Always release air and fluid pressure before cleaning, disassembling
or servicing. Otherwise, remaining pressure can cause bodily injury due
to improper operation or scattering of cleaning liquid.
4. Tip of fluid needle set has a sharp point.
Do not touch the tip during maintenance to avoid accidents.
5. Never use this gun to spray foods or chemicals.
Otherwise, foreign substance, could cause corrosion of fluid passages
which could adversely affect health.
HOW TO USE
CAUTION
- Use clean air filtered through air dryer and air filter.
- When using this gun for the first time after purchase, adjust fluid nee-
dle packing set, spray cleaner to clean fluid passages and remove rust
preventive oil.
1. Firmly connect an air hose to air nipple 1/4".
2. Firmly connect a suitable cup to fluid nipple.
3. Flush fluid passages with a compatible solvent.
4. Pour paint into container, test spray, adjust fluid output and pattern width.
HOW TO OPERATE
Suggested atomizing air pressure is 2.0 to 3.0 bar (29 to 44 PSI) at gun
inlet.
Paint viscosity differs according to paint property and painting conditions.
12 to 23 sec. / Ford cup#4 is recommended.
Set the spray distance from the gun to the work piece, as near as possi-
ble within the range of 100-200 mm (3.9-7.9 in).