Step 4: Additional Protection (optional)
• Coldbuster recommends the application of a thin layer of flexible tile adhesive over the laid heating in
order to give the element protection from accidental damage caused by removal of the floor covering
in the future
• Spread the tile adhesive evenly over the heater with a steel float (with rounded corners)
• Ensure the element stays in position and the adhesive penetrates through the mesh with complete
coverage
• Allow the tile adhesive to set

Multiple Heater Installation

• If you are installing multiple heaters into one single heat zone (and thus using one thermostat), each
heater will need to start at the thermostat location
MULTIPLE heaters must be connected in PARALLEL
• As explained earlier, you may need to cut the mesh between the elements (without cutting the
heater element) to enable the heater to be laid in a single line, leading to the start of the next run
(from cold tail to heating element) to touch or cross each other
• Remember to maintain a spacing of 60-80mm when laying the heater element freehand. Laying the
element further apart than suggested may result in cooler areas
Do not allow different elements or factory connections