Coldtainer F0140/NDN Manuel de l'utilisateur - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Coldtainer F0140/NDN. Coldtainer F0140/NDN 16 pages.

Coldtainer F0140/NDN Manuel de l'utilisateur
directly to the + and – terminals of the battery from the other side (or to the 12V
outlet of the car, on applicable models).
The DC cords are fuse protected. Make sure that the fuse is in place. Also the DC
input connectors on the fridges are fuse protected. See technical data sheet for
fuse size.
o
- U
ptional
se of the
It is possible to operate your unit connected to the AC mains by the use of external
AC-DC power supplies of proper technical features, available as accessories. Three
models are available, with 150W, 300W and 600W rated power. Verify the right
model suggested for each model.
Note: the AC-DC power supplies are provided without the AC plug. It is
responsibility of the user to install a proper Country approved plug. Ask a qualified
personnel to do it.
The power supplies available as accessories have a worldwide input voltage (100-
240Vac 50/60Hz) and a constant 13Vdc output, are IP65 rated and CE and UL/CSA
certified. On the DC output line there is a yellow AP connector.
Connect the AC-DC power supply to the specific DC inlet (yellow AP connector)
on the fridge.
Both DC lines can be connected at same time. In this case the "yellow" line will
be the preferred power supply source. As soon as an internal relay will sense no
voltage coming from the "yellow" line it will reconnect the "red" line from battery.
On all models it is possible to fasten the power supplies in special receptacles
inside the silhouette of the containers (except T0022, T0032).
Note: T0022 and T0032 have a single red connector. To use that models with
the external 150W AC-DC power supply, a "red-yellow" connectors interface is
available as accessory.

ELECTRICAL CONNECTIONS, "AUTONOMOUS OPERATION" MODELS

The "Autonomous Operation" models are equipped as standard with internal
battery pack (single battery for the "Light Capacity" models, multiple battery pack
for the "High Capacity" models) and with a battery charger.
The "AuO" models are intended to operate fully independently, connected only
to their internal 12 power source. No connection to external DC power source is
provided. The internal battery protection will monitor the voltage of the battery
and eventually switch off the compressor.
C
onneCtion to
To recharge the internal battery pack, connect the battery charger to the AC mains
(100-240Vac 50/60Hz) and switch it on (by its own main switch). The battery will be
recharged with a proper charging curve.
With the battery charger connected to the AC mains and on it is possible at the
same time to operate the unit and to recharge the battery (with longer battery
6
C
oldtainer ConneCted to
aC
(100-240V
mains
aC
mains
50/60 h
)
aC
z
(100-240V
50/60 h
aC
)
z