Precautions before turning on the Master Controller Power Switch:
Do not connect or disconnect any cables while the power is turned on.
Do not connect the CAT5 cable from the motor to any other port besides the MTR
LOGIC port. The motor may become damaged if plugged into any other port.
Do not connect a Touch Screen that is labeled Touch Panel to any other port besides
Touch Panel A or B.
Do not connect a Touch Screen that is labeled Keypad to any other port besides the
Bio/Keypad port.
Getting started:
Before powering on the Master Controller, be sure that the door can move freely by
hand from one side to the other. Be sure that the door is able to touch the Home
Switch located on the track.
Upon powering up the system, the door will make two small 1/8" diagnostic moves,
then will start to move very slowly towards the fully open position. If the systems exhibits
any behavior OTHER than moving slowly towards HOME(fully open), quickly turn off the
power. If the door begins the homing process towards the CLOSED position, then the
belt has been installed in reverse. It is advised that when powering the system up for
the very first time that you have easy access to the motor and Master Controller. It is
ideal to be able to see the door from the Master Controller while programming.
The primary settings required to be adjusted by the user are:
Set Closed Position, Closing Trip Level, Set Max Torque
All settings designated as "Factory Settings" should never be changed without
consulting Dado Door.
In the event of the system become inoperable, before powering off the Master, look at
the LCD display and see if any error messages are present. For a detailed explanation
of error messages, see the error listing section later in this guide.
NOTE: The default distance the door is set to move is 20". You will need to adjust the
Set Closed Position to your requirements. If your door is required to move LESS than 20",
be sure to adjust this Closed Position BEFORE attempting to test the system. Do not
allow the door to contact the door jamb.