FEATURES (cont'd)
Touch Screens: There are two versions of wall mounted touch screens available.
These touch screes are not required to operate the door. The Standard Touch Screen
has a large main area for door toggle, this area is indicated by two arrows together
and is a one-touch button. There are smaller touch areas indicated by the < and >
arrows for positioning the door anywhere between the extremes of full open or full
closed while the arrows are pressed. There is a lock area with a corresponding LED to
display whether the door is locked or unlocked. We offer a fingerprint/keypad
keypad panel in a Keypad Touch Screen. The Keypad can be used for passcode
entry. The optional fingerprint sensor can store up to 1000 users in the database.
Software Features: The electronics and software are our own proprietary design.
There- fore, the hardware and software can be custom configured to any
requirement. The standard options are as follows:
Locking Features: Port B is designated as a locking master sTouch Screen. A secret
unlock method can be provided as required to prevent accidentally being locked
out of a room or for emergency purposes. Port B is typically the port that will be used
as a Locking Touch Screen inside the room. Port A it typically the outside Touch
Screen.
Auto Home: Upon each power up, the system automatically moves towards a Home
switch which is located on the track near the motor. After Homing, the system
operates normally.
Parameters and Settings: There are basic user settings and advanced settings for
motion control to achieve the best possible motion for any door weight and size.
Each setting is stored in permanent memory and cannot be lost due to power failure.
Upon a power outage, when the power comes back on, the door moves to it's
Home position(fully open), and all parameters remain as they were prior to the
power outage.
Auto Close: Automatic close mode can be enabled, whereas after a user defined
delay period(0 - 60 seconds), the door will automatically close after it is has been
opened.
Auto Retract on obstruction or door jam: If the door is closing and encounters an
obstruction(unusual pressure), it will retract automatically to the fully open position.
There is a parameter to set this threshold of pressure that must be exceeded before
retracting(Closing Trip Level). The method of determining pressure is done by using a
current sensing circuit on the motor driver board. The software monitors the current
levels and detects if the levels have exceeded the user-defined Trip Level.