Basic Serial Functional Specification for LV-5210/7215/7210
7.6 Setting Read COMMAND
COMMAND
"CR4" [CR]
Detail
Get setting status for screen such as Ceiling/Rear.
Acceptable
Response
Unacceptable
7.7 Temp Read COMMAND
COMMAND
"CR6" [CR]
Get the temperature inside a projector.
Detail
When some temperature sensors are installed in the projector, it is possible
to know the temperature all at once.
Response
Acceptable
Unacceptable
"%1" [CR]
"11" [CR] = Normal Screen Setting
"10" [CR] = Rotation around the horizontal setting (Rear&
Ceiling ON)
"01" [CR] = Rotation around the horizontal setting Rear
%1
ON)
"00" [CR] = Vertical and right-and left (four directions)
reversal setting (status: Ceiling ON
"?" [CR]
"%1_%2_%3" [CR]
%1=Temperature, sensor 1
%2=Temperature, sensor 2
%3=Temperature, sensor 3
Temperature data form shows as 00.0.
When the temperature sinks to -, the first character is "-"
like "-05.5" [CR].
When cannot return the temperature data due to hardware
problems, the first character is "E" like"E00.0" [CR].
%1
When the status is Stand BY or it is 10 seconds after Power
%2
On, depend on projectors, temperature may approach critical
%3
temperature due to ballast lamp's residual heat. So, when
the status is Stand By or it is 10 seconds after Power On, the
process for the abnormal temperature is not executed.
temperature data is " ----" at the time.
When some temperature sensors are installed, the projector
sends command continuously.
"_31.5__35.2__33.4" [CR]
There is the first sensor's information, and after one space,
there is the second sensor's information.
"?" [CR]
)