Canon LV-7392A Spécifications des commandes - Page 26

Parcourez en ligne ou téléchargez le pdf Spécifications des commandes pour {nom_de_la_catégorie} Canon LV-7392A. Canon LV-7392A 26 pages. Lv series multimedia lcd projectors
Également pour Canon LV-7392A : Spécifications (2 pages)

Canon LV-7392A Spécifications des commandes
LV-7292A/LV-7297A/LV-7392A/LV-7393A/LV-7398A/LV-8227A/LV-7292M/LV-7297M/
Unacceptable

7.9. Lamp Mode Read Command

Command
"CR7" [CR]
Get lamp mode status.
Detail
For 1 lamp projector, get if it is lighting or not.
Acceptable
Response
Unacceptable
LV-8227M/ LV-7292S/LV-7297S/LV-7392S
%1 Temperature of sensor 1
%2 Temperature of sensor 2
%3 Temperature of sensor 3
Temperature data is shown as "00.0".
When the temperature goes down to -, the first character
%1
becomes "-" instead of a space, like "-05.5" [CR].
%2
When no temperature data can be returned due to hardware
%3
problems, the first character becomes "E" like"E00.0" [CR].
When several temperature sensors are equipped, Responses are
returned continuously.
"_31.5 _ _35.2 _ _33.4"[CR]
The first data is sensor 1, then one space, and the data of sensor
2 follows.
" "[CR]
"%1" [CR]
"00" [CR]=Light is out.
%1
"01" [CR]=Light is on.
" "[CR]
-23-