Diodes are required for inductive loads such as electric strikes/locks. Failure
to use appropriate diodes will void the reader warranty.

TERMINAL STRIPS AND CABLE

Use MARR Connectors
If you are bringing in cable that is too large for the terminal
strip, use a MARR connector (wire nut, marrette, thimble
connector, cone connector). Splice the thicker cable to a cable
that is the appropriate thickness, and then run the thinner
cable to the terminal strip on the control panel.
Use Splices for Parallel Wiring
The terminal strips are designed to allow one cable per hole.
If you need to connect multiple cables in a single hole, use a
MARR connector (wire nut, marrette, thimble connector,
cone connector). Splice multiple cables to a single cable, and
then run the single cable to the terminal strip on the control
panel.
NOTE: When determining power supply current requirements, you must consider lock
and reader current draw if using the same supply for these devices.
Installation of magnetic locks is not supported with this reader
NOTE:
NOTE: The lock must have a diode installed to prevent "back EMF" from
damaging the reader.