DOTECH FX3S Manuel de l'utilisateur - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} DOTECH FX3S. DOTECH FX3S 4 pages. Digital temperature control
Dimensions and Panel Cut-Out Form
78
Wiring
FX3S
16A, 250Vac
POWER
SUPPLY
L1
L2
c
1 2
4 5 6
100-240Vac,
OUT1
50/60Hz
FX3S-00-T
POWER
SUPPLY
+
-
1 2
12Vdc
Constitution
(Function of Display Lamp and Button)
FX3S
OUT1
Display Message
Code
Menu
Natural defrost
DEF
Trip / AlarmLARM MESSAGES
Code
Menu
Internal
SYS
Parameter Error
Sensor Open
OPN
Sensor Short
SHT
Lower Input
LLL
Higher Input
HHH
※
In case of error occurring, the following messages are flickering at every 0.5 sec. intervals.
8
35
NTC
COM
NTC
8 9
FX3S-00-H
POWER
SUPPLY
+
-
1 2
24Vdc
/ 48Vdc
Description / Instructions
Present temperature and DEF message display by turns at natural defrost.
Description / Instructions
In Case of change of set value by an unknown case.
In case of Input sensor open wire(Normal operation after sensor connecting)
In case of Input sensor short circuit
Lower sensor input than measuring range
Higher sensor input than measuring range
70
28
40
UNIT : mm
No
Label
1
POWER
2
4
OUT1
5
(Relay output)
6
8
SENSOR
(NTC)
9
OUT1
Turn on when output #1 is ON (Flickering at standby)
Celsius / Fahrenheit display units
°C / °F
LED
ON at trip, Flickering at alarm
Parameter set up locked
PRG
Use at program setup
SEL
Execute selected menu or Input setup value
Move between menus & Increase setup value
BUTTON
▲
Move between menus & Decrease setup value
▼
If pushing for 10 sec. at the same time ,
PRG + ▼
setup value is initialized
- 2 -
90
(Panel Cut-Out : 71mm X 29mm)
Description
100-240Vac, 50/60Hz
Relay output OUT1 when closed
Common signal
Relay output OUT1 when open
Common signal
Temperature sensor input
Response at
Detection
Immediate Stop
Response at
Detection
Immediate Stop
Immediate Stop
Immediate Stop
Immediate Stop
Immediate Stop
Reset Type
Reset Type
Automatic Reset
Automatic Reset
Automatic Reset
Automatic Reset
Automatic Reset
R20160721