Electra Light E-Line Manuel de l'utilisateur - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Electra Light E-Line. Electra Light E-Line 7 pages. Electra light e-line 575w moving head user manual
USER MANUAL – E-LINE
○ Operation guide
575 use the Digital display to control DMX address set-up.
●
575 Moving Head adopts international standard DMX-512 signal, multiple lights can be
●
controlled by the consol via address code setting (the details are listed in Appendix 3)
The original address code set-up before the products leave the factory:
●
patterns and colors streamline, X,Y axis is the positive direction
Use the XLR-XLR cable from the signal output port of the consol to connect the signal input
●
port of the first light, connect the signal output port of the first light with the signal input port of
the second light, and so on, until all lights are connected. Then connect the terminal plug with
the signal output port of the last light. (Figure Appendix 1)
Warning: Please remember the signal output of the last light should be connected with the
terminal plug. This plug add a resistance around 120Ω between 2nd and 3rd pin of CANON
plug. Use this plug could effectively avoid the signal reflection created during DMX512 signal
transmission.
575 Moving Head Light uses 3 core XLR outlet(plug). A transfer line from 5 core to 3 core
●
will be needed if the controller you use is 5 core outlet (plug). (Please refer to Appendix 2)
HMI 575W lamp is discharge lamp, it is fully illuminated about 5-10 minutes after power is
●
on. In the meantime, please restart about 10 minutes after power is off.
When power is on, the equipment will undertake self-examination, and can undertake
●
operation after the self-examination is finished.
Please don't shake the equipment during operation.
●
Please do not use the light continuously for over 8 hours.
●
3