Doug Fleenor Design NODE16-DIN Configuration et manuel d'utilisation - Page 2
Parcourez en ligne ou téléchargez le pdf Configuration et manuel d'utilisation pour {nom_de_la_catégorie} Doug Fleenor Design NODE16-DIN. Doug Fleenor Design NODE16-DIN 6 pages. Sixteen output ethernet to dmx512 interface
Product description
N
16 is an Ethernet to DMX512 bridging device. It accepts Streaming ACN (ANSI
ODE
E1.31) or Artistic License's Art-Net protocols. There are sixteen fully isolated DMX512
output ports. The Ethernet input connector accepts standard RJ45 (8P8C) connectors as
well as Neutrik Ethercon plugs.
Each of the sixteen outputs has two front panel indicators: A signal LED which illuminates
if there is DMX512 data for the selected universe, and a mimic LED which mimics the
output level of DMX512 slot one (channel one) of the selected universe (useful for
troubleshooting). A red power indicator, a green network link indicator, and a yellow
network activity indicator are also provided.
The factory default configuration covers most applications. Default configuration is
editable using the front panel encoder wheel and backlit LCD.
N
16 is powered by 100-240VAC 50/60 Hz, 30W. It fits in one unit (1.75") of 19 inch
ODE
rack space.
Environmental
Operating temperature: 0-40º C (32-104° F)
Operating humidity: 10-90% non-condensing
Indoor use only.
Jumper settings
Five configuration jumpers are located inside N
time. Jumpers should be set prior to installation. Jumper functions are described in the
table below.
Jumper
JP1
Front panel encoder allows configuration
changes.
JP2
No function at this time
JP3
No function at this time
JP4
No function at this time
JP5
No function at this time
Output Port Specifications
Port circuit:
Output signal:
Connectors:
Port protection:
Isolation:
Network Specifications
Input circuit:
Input signal:
Input connector:
MDIX:
Installed function
Protected EIA-485 receiver (ADM2795).
1.5 Volts (minimum) into 120 Ohm Termination.
Sixteen 5-pin female XLRs on rear panel.
±42V continuous, ±15KV transient.
1,500 Volts isolation from Ethernet input and from other outputs.
802.3 Ethernet compliant input (LAN8720).
Art-Net or sACN (ANSI E1.31) Ethernet protocols.
Ethercon RJ45 (8P8C) on front panel.
Auto-negotiated.
16. Only JP1 has a purpose at this
ODE
Front panel encoder is disabled.
Editing is locked out.
No function at this time
No function at this time
No function at this time
No function at this time
Page 2 of 6
Removed function