5.1 PL20S mounting
DANGER
Risk of injury from hazardous medium
Wear protective equipment for hazardous media (e.g. acids, alkaline solutions).
f
„
Empty vessel and pipelines before mounting.
f
„
1
2
www.baumer.com
PTFE
Operating Instructions
Level measurement
CleverLevel
Adaptive trigger – hygienic/industrial
PL20S with the following process connections:
G 1/2 A ISO 228-1 (BCID G07)
„
„
1/2-14 NPT (BCID N02)
„
„
9 Vessel and pipelines are free of media.
Seal thread on sensor with Teflon tape (PTFE).
f
„
Screw in sensor.
f
„
G 1/2 A tightening torque: 30 Nm max.
NPT tightening torque: 20 Nm max.
PL20S with the following process connections:
G 1/2 A ISO 228-1 (BCID G07) with industrial
„
„
weld-in sleeve for universal use, Ø 30 x 26
(ZPW1-711, ZPW1-721)
G 1/2 A hygienic (BCID A03) with weld-in sleeve
„
„
or adapter from Baumer
G 1/2 A DIN 3852-E (BCID G51)
„
„
For these process connections, do not seal with
Teflon tape (PTFE) or elastomer.
9 Vessel and pipelines are free of media.
9 Adapter or weld-in sleeve are mounted free of
dead space.
Screw in sensor.
f
„
Tightening torque: 15 ... 20 Nm
®
PL20H/S