Check the mechanical installation. The sensor must be parallel to the stream.
Check the Application setting; DIP 5-8.
Check the interface. See previous page.
If the product stream is very irregular, it could be that the sensor is blocking out
products coming too close. Try choosing an application with a shorter blocking.
See chapter 4, "SOFTWARE FUNCTIONS".
Make sure that the stacker has not got an internal Blocking Zone which is set in a
way that it blocks out pulses from the sensor.
If the product with the problem is very black and very thin, try lowering the sensor 10-
20 mm closer to the product stream.
Are the products very tilted when they pass the sensor? The max angle allowed is
15° for a 0.25 mm product.
9.1

Maintenance at Regular Intervals

To ensure the best operation, by following the steps above:
• Clean the glass aperture with alcohol to remove ink dust.
• Remove any loose pieces of paper that can produce false counts
• Check that the target plate is still mounted the way it should be
User Manual DENEX Edge Detector II
Version 2013-02, V1.6
14/20
www.baumer.com
Baumer Electric AG
Frauenfeld, Switzerland