5

Terminal assignment

5.1 2 x M12 flange connector, 5-pin

Pin
Assignment
1
CAN_GND
2
+Vs
3
GND
4
CAN_H
5
CAN_L
Terminals with the same designation are connected to each other internally and identical in their functions.
Maximum load on the internal clamps Vs-Vs and GND-GND is 0.6 Amps each.
Baumer_GIM700DR_SAEJ1939_EN_V1.00_MNL.docx
27.04.2021
Description
Ground connection relating to CAN
Voltage supply
Ground connection relating to +Vs
CAN Bus signal (dominant High)
CAN Bus signal (dominant Low)