7.0 T
P
YPICAL
ERFORMANCE
60
50
40
30
20
10
0
0.1
Figure 6: Typical Impedance compared to CISPR 25 & CISPR 16-1-2 requirements
100
90
80
70
60
50
40
30
20
10
0
-10
-20
0.1
1 9 1 2 1 E l T o r o R d ● S i l v e r a d o , C a l i f o r n i a 9 2 6 7 6 ● ( 9 4 9 ) 4 5 9 - 9 6 0 0 ● c o m - p o w e r . c o m
D
ATA
1
10
Frequency (MHz)
1
10
Frequency (MHz)
Figure 7: Typical Phase compared to CISPR 16-1-2 requirements.
LI-550C LINE IMPEDANCE STABILIZATION NETWORK
100
100
Page 14 of 16
INSTRUCTION MANUAL
LISN Impedance
CISPR 16-1-2, Ed.1.2, Tbl 5
(5uH) Impedance Limits
(±20%)
CISPR 25, Ed.3 (5uH)
Impedance Limits (±20%)
1000
LISN Phase
CISPR 16-1-2, Ed.1.2, Tbl 5
(5uH) Phase Limits
(±11.5°)
1000
REV021317