Port
Alarm I/O
1.2
Connecting Alarm Input/output
Alarm input/output is available on select models.
Step 1
Connect alarm input device to the alarm input end of the I/O port. See Figure 1-2.
Device collects different states of alarm input port when the input signal is idling and
grounded.
Device collects logic "1" when input signal is connecting to +3V to +5V or idling.
Device collects logic "0" when input signal is grounded.
Step 2
Connect alarm output device to the alarm output end of the I/O port. The alarm output is
relay switch output, which can only connect to NO alarm devices.
The ALARM_NO port and the ALARM_COM port with the same number constitute a switch
for alarm output. See Figure 1-3. The switch is open normally and closes when there is alarm
output.
Table 1-2 Alarm I/O port introduction
Port Name
ALARM_IN (pin1–pin3)
GND (pin4)
ALARM_NO1 (pin5)
ALARM_NO2 (pin7)
ALARM_COM1 (pin6)
ALARM_COM2 (pin8)
Description
Receives the switch signal of external alarm source.
Connect all the alarm input devices to the same GND
port.
Outputs alarm signal to alarm output device.
When connecting to alarm output device, only the
ALARM_NO port and ALARM_COM port with the same
number can be used together.
Figure 1-2
Alarm input
2
Quick Start Guide