ATTENTION
The product shall be appropriately protected by an extern fuse or R/C.
NOTE
For test installations a cable with the order code 11213075 (ZCABL-
ALL.AMP0300) may be used.

2.4 Visual Diagnostic

High luminosity LEDs provide quick feedback on the operational status of the sensor. The
LEDs are positioned behind the radar lens and may be observed even under bright ambient
light. The following table indicates sensor status and LED blink codes.
Tab 5
Status Mapping (Visual Diagnostic)
Status
Sensor fully operational (ob-
ject detected)
Sensor fully operational, (no
object detected)
Hardware fault
CAN Bus Off (malfunction)
Address claim failed
Waiting for Master ECU ad-
dress claim
Other
Page 16 of 29
Code
100ms Green LED ON
400ms LED OFF
Green LED as above, with additional
100ms Yellow LED ON in "LED OFF" interval
50ms Red LED ON
50ms LED OFF
50ms Magenta LED ON
150ms LED OFF
50ms Magenta LED ON
50ms LED OFF
500ms Magenta LED ON
500ms LED OFF
Blue LED
R600V.DAE0_manual_1.5 (EN).docm