Baumer R600V.DAE0-11228779 Manuel d'utilisation - Page 24
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Baumer R600V.DAE0-11228779. Baumer R600V.DAE0-11228779 29 pages. Off-highway ground & crop radar sensor
Manual R600V.DAE0 (EN)
4 Trouble Shooting
Tab 15 Trouble Shooting Overview
Failure
No function, no LED
Function impaired, thick layer of dirt
Mechanical damage to housing
and/or lens
Unexplained targets / distance meas-
urement in near range
Unexplained targets / distance meas-
urement in far range
The LED is blinking red (50ms on /
50ms off)
The LED is blinking magenta
The LED is blinking blue for a long pe-
riod.
No communication (also magenta
blinking)
5 Accessories
The following accessories are available for this product
Tab 16 Accessories
Art. no.
Description
11213075
ZCABL-ALL.AMP0300
Page 24 of 29
Action
Check cables, connections, power supply at pins
Clean lens and remove excess water.
Replace part by qualified personnel.
Check free space (or beyond) for non-stationary objects (such as dangling wires,
tubes, water drops on surfaces.
Check for double reflections, and limit measurement range
Hardware fault. Replace part by qualified personnel
CAN bus error. Check Tab 5 for details.
Try a power cycle. If this does not fix the issue replace part by qualified personnel
Check CAN speed (e.g. 250kbit/sec), check 120Ohm termination,
Type
Connector AMPSEAL 16 with
PUR-cable
Comment
3m cable with AMPSEAL connector
and fly-leads
R600V.DAE0_manual_1.5 (EN).docm