ELECTRICAL CONNECTION / SPEED SWITCH AND ADDITIONAL OUTPUT INCREMENTAL
5.2.5
Cable connection
)
To ensure the specified protection of the device the correct cable diameter must
be used�
Connecting cables are not in scope of delivery�
Cable shield
MB250EN - 11173966, 17A2, Baumer_HMG10-CANopen_II_EN
22
21
22 mm
Mt = 2-3 Nm
TX 20
20
19
19
Terminal box cover
20
Torx and slotted screw,
M4x32 mm
21
Cable gland M20x1�5 mm
for cable ø5-13 mm
22
Connecting terminal,
core cross-section ≤1.5 mm
Connecting cable
ø5-13 mm
Connecting terminal [ B ]
Speed switch/additional output
See
section
5.2.6.1�
2
20/33