Baumer EAM580R-SY Manuel - Page 22

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Baumer EAM580R-SY. Baumer EAM580R-SY 27 pages. Absolute encoder with sae j1939

Baumer EAM580R-SY Manuel
9.9

0x2104 Transmission rate for PGN65450

The transmission time is a 16-Bit value, which is in Byte 4 and Byte 5 and has the unit [ms].
Example of changing the transmission Rate to 500 ms (1F4h)
Description
Changing of transmission time to 500ms
Successful response by encoder (60h)
Optional Send saving of all parameters
Optional Successful response by encoder
(60h)
Example of Reading tPGN65450 transmission time
Description
Read transmission time of encoder
Response by encoder with 1F4h
Baumer_EAM580_360_EB360_SAE_J1939_MA_EN_Rev0003.0000h_Index0004.docx
05.12.2022
Identifier
DLC
18EFAC00h
8
22
18EF00ACh
8
60
18EFAC00h
8
22
18EF00ACh
8
60
Cyclic PGN65450 is sent every 500ms
Identifier
DLC
18EFAC00h
8
40
18EF00ACh
8
4B
22/27
Protocol Data Unit (PDU)
Byte 0 ... 7 [hex]
04
21
00
F4
04
21
00
00
10
10
01
73
10
10
01
00
Protocol Data Unit (PDU)
Byte 0 ... 7 [hex]
04
21
00
00
03
21
00
F4
01
00
00
00
00
00
61
76
65
00
00
00
00
00
00
01
00
00
Baumer Electric AG
Frauenfeld, Switzerland