Baumer HOG 161 Instructions de montage et d'utilisation - Page 29
Parcourez en ligne ou téléchargez le pdf Instructions de montage et d'utilisation pour {nom_de_la_catégorie} Baumer HOG 161. Baumer HOG 161 32 pages. Incremental encoder
9
Technical data
9.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
9.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
MB090T1 - 11055700
9...30 VDC (HTL)
9...26 VDC (TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
250...2500 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz
K1, K2, K0 + inverted
HTL
TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E217823
ø158 mm
ø38...75 mm (through hollow shaft)
≤350 N axial, ≤500 N radial
IP54
≤6000 rpm (mechanical)
15 Ncm
26,3 kgcm
Housing: aluminium alloy
Shaft: stainless steel
-40...+85 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T100°C Dc (dust)
Terminal box
2x terminal box (option M)
4.5 kg (ø48), 3.2 kg (ø75), 3.6 kg (ø75 option M)
Baumer_HOG161-HOG161M-T1_II_DE-EN (20A1)
(ø48), 13,5 kgcm
(ø75)
2
2
Technical data
9
26