10
Technical data
10.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Shaft insulation:
• Transmission length:
• Interference immunity:
• Emitted interference:
• Approvals:
HOG 86 M
• Operating principle:
10.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Shaft loading:
• Motor shaft tolerance:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque:
• Rotor moment of inertia:
• Materials:
• Resistance:
• Corrosion protection:
• Explosion protection:
HOG 86
• Operating temperature:
• Connection:
• Weight approx.:
HOG 86 M
• Operating temperature:
• Connection:
• Weight approx.:
* Up to -25 °C for versions >3072 pulses per revolution
MB194 - 11072323
9...30 VDC (HTL, TTL - version R)
5 VDC ±5% (TTL)
≤100 mA
500...5000 (As ordered)
90° ±20°
45...55 %; 40...60 % (>3072 pulses per revolution)
Zero pulse, width 90°
Optical
≤170 kHz; ≤300 kHz option
K1, K2, K0 + inverted; Error output (only EMS)
HTL-P (power linedriver); TTL/RS422 (As ordered)
2.8 kV
≤350 m at 100 kHz (HTL-P); ≤550 m at 100 kHz (TTL)
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE, UL/CSA approval / E256710
Redundant sensing
ø99 mm
ø12...16 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
≤350 N axial; ≤450 N radial
0.2 mm radial
IP66
≤10000 rpm (mechanical)
≤6 Ncm
160 gcm
Housing: aluminium; Shaft: stainless steel
IEC 60068-2-6:2007, Vibration 20 g, 10-2000 Hz
IEC 60068-2-27:2008, Shock 250 g, 6 ms
IEC 60068-2-52 salt mist complies to
ISO 12944-5:1998 protective paint systems (C4)
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
-40*...+100°C, -40*...+90 °C (fixed cable)
Restricted in potentially explosive environments, see section 2.
Terminal box, flange connector M23, 12-pin, cable 1 m
1.3 kg
-40*...+100 °C
Restricted in potentially explosive environments, see section 2.
2x terminal box
1.4 kg
Baumer_HOG86-HOG86M_II_DE-EN (16A3)
2
10
Technical data