9

Technical data

9.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Sinewave cycles per turn:
• Phase shift:
• Reference signal:
• Sensing method:
• Output signals:
• Output stage:
• Difference of SinCos amplitude: ≤20 mV
• Harmonics typ.:
• DC offset:
• Bandwidth:
• Interference immunity:
• Emitted interference:
• Approvals:
9.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Operating speed:
• Starting torque:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Explosion protection:
• Connection:
• Weight approx.:
MB175aT1 - 11173568
5 VDC ±10 % (version DN ...)
9...26 VDC (version DN ... R)
≤90 mA
1024...2048 (as ordered)
90°
Zero pulse, width 90°
Optical
K1, K2, K0 + inverted
SinCos 1 Vpp
-50 dB
≤20 mV
200 kHz (-3 dB)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E256710
ø75 mm
ø17 mm (cone shaft 1:10)
≤170 N axial
≤250 N radial
IP56
≤10000 rpm (mechanical)
≤4 Ncm
180 gcm²
Housing: aluminium die-cast
Shaft: stainless steel
-20...+70 °C
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 48 g, 10-2000 Hz
IEC 60068-2-27
Shock 200 g, 6 ms
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
Connecting cable
860 g
Baumer_HOGS75K-A-T1_II_DE-EN (19A1)
9
Technical data
24