Baumer Hübner
7.1

Uninstall when using EURO flange B10

7.1.1

Uninstall encoder from drive shaft

DANGER
Burns caused by heat
The device heats up at high speeds. There is a risk of getting burned after use.
a) Avoid overheating the device.
b) Wear suitable protective gloves and clothing.
Ill. 15: Uninstall encoder, mounting device and coupling
1
Coupling
3
Attachment device, customized
Tools
2.5 mm
n
n
V1 | PMG10 & PMG10P EtherNet/IP
1
10 mm
2
3
2
Mounting screw M6x16 mm for attach-
ment device (ISO 4017)