Baumer HUBNER BERLIN POG 10 ETL Instructions de montage et d'utilisation - Page 7

Parcourez en ligne ou téléchargez le pdf Instructions de montage et d'utilisation pour {nom_de_la_catégorie} Baumer HUBNER BERLIN POG 10 ETL. Baumer HUBNER BERLIN POG 10 ETL 28 pages. Incremental encoder

2
Operation in potentially explosive environments (only with option ATEX)
The device meets the design requirements of equipment category 3 G, Equipment Group II
(explosive gas atmosphere) and of equipment category 3 D, Equipment Group III (explosive
dust atmosphere). Conformity in accordance with the directive 2014/34/EU.
CE labeling:
Category 3 G:
Category 3 D:
The operation in other explosive atmospheres is not permissible.
Danger of personal injuries and damage due to inappropriate installation and operating.
Contravention invalidates the EX approval.
An UL listing that may be stated elsewhere is not valid for use in explosive environments.
It is not permissible to make any alteration to equipment that is used in potentially explosive
environments.
Repairs may only be carried out by authorized authorities provided by the manufacturer.
• Ensure that there is no explosive atmosphere, oils, acids, gases, vapors, radiation etc.
present when mounting.
• Mounting and operating in accordance with the stipulations of the mounting and operating
instructions.
• The relevant laws, regulations and standards for the planned application must be observed.
The norm EN 60079-14 must be observed when mounting and operation.
• Check that the details on the type label of the device match the on-site conditions for the
permissible Ex area in use (equipment group, equipment category, zone, temperature
class, maximum surface temperature).
• Check that the details on the type label of the device match the electrical supply network.
• Check that the device is undamaged. Ensure the IP protection.
• Check the dust deposit. Any possible dust deposit does not exceed a thickness of 5 mm.
• Do not exceed or underrun the ambient temperature range from -20 °C to -40 °C.
MB069b - 11117426
BAUMER_POG10-ET_DE_EN_202212_MI_11117426 (22A3)
Operation in potentially explosive environments (only with option ATEX)
- Ex labeling:
- Normenkonformität:
- Type of protection:
- Temperature class:
- Ex labeling:
- Conforms to standard:
- Protective principle:
- Surface temperature:
II 3 G Ex ec IIC T4 Gc
EN IEC 60079-0:2018
EN IEC 60079-7:2015 +A1:2018
ec
T4
II 3 D Ex tc IIIC T135°C Dc
EN 60079-31:2014
Protection by enclosure
max. +135 °C
4