Baumer HUBNER BERLIN PROFI NET microGen HMG10 Instructions de montage et d'utilisation - Page 19
Parcourez en ligne ou téléchargez le pdf Instructions de montage et d'utilisation pour {nom_de_la_catégorie} Baumer HUBNER BERLIN PROFI NET microGen HMG10. Baumer HUBNER BERLIN PROFI NET microGen HMG10 32 pages. Absolute encoder profinet with magnetic sensing
5.2.2.2
Trigger level
Trigger level:
High / Low:
Transmission length:
Output frequency
Trigger level:
High / Low:
Transmission length:
Output frequency
)
5.2.3
Programming interface (only HMG10P)
Via connection SA and SB, encoder parameters such as additional output, switch-off
and switch-on speeds can be changed and read out� With the Z-PA�SDL�1 WLAN
adapter, available as accessory, see
web browser�
5.2.4
LED function displays
LED
INC1
INC2
(additional output
incremental)
Status
Speed
MB248EN - 11171699, 19A2, Baumer_HMG10-PROFINET_II_EN
Electrically isolated: The TTL/HTL (Vin = Vout) output at the additional
output incremental is electrically isolated and requires a separate power
supply�
Red
Without function
Undervoltage
Overload
Over-temperature
Internal error
Speed higher switching speed Speed lower switching speed
(overspeed)
ELECTRICAL CONNECTION / TERMINAL BOX [B]
TTL/RS422
≥2.5 V / ≤0.5 V
≤550 m @ 100 kHz
≤600 kHz
TTL/HTL (Vin = Vout)
≥2.5 V / ≤0.5 V (TTL)
≤550 m @ 100 kHz (TTL)
ǀ
≤600 kHz (TTL)
≤350 kHz (HTL)
section
5.3, the encoder can be accessed via a
ǀ
≥Ub -3 V / ≤1.5 V (HTL)
ǀ
≤350 m @ 100 kHz (HTL)
Green
Without function
OK
OK
16/27